A.2 Parameter Table
YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual 317
Parameter List
A
E1-04
Max Output
Frequency
These parameters are only applicable when
E1-03 is set to F. To set linear V/f
characteristics, set the same values for E1-07
and E1-09. In this case, the setting for E1-08
will be disregarded. Ensure that the four
frequencies are set according to these rules:
E1-04 ≥ E1-06> E1-07 ≥ E1-09
40.0 to
400.0
<21>
50 Hz
<10>
SSS 303 115
E1-05
<24>
Max Output
Vo l t a g e
0.0 to
255.0
200 V
<10>
SSS 304 115
E1-06
Base
Frequency
0.0 to
E1-04
50 Hz
<10>
SSS 305 115
E1-07
Mid Output
Frequency
0.0 to
E1-04
2.5 Hz
<2>
AA - 306 115
E1-08
<24>
Mid Output
Frequency
Vo l t a g e
0.0 to
255.0
16.0 V
<2>
<12>
AA - 307 115
E1-09
Minimum
Output Freq.
0.0 to
E1-04
1.3 Hz
<2>
<10>
SSS 308 115
E1-10
<24>
Minimum
Output Freq.
Vo l t a g e
0.0 to
255.0
12.0 V
<2>
<12>
AA - 309 115
E1-11
<26>
Mid Output
Frequency 2
0.0 to
E1-04
0.0 Hz A A - 30A 115
E1-12
<24>
<26>
Mid Output
Frequency
Voltage 2
0.0 to
255.0
0.0 V A A - 30B 115
E1-13
<24>
Base Voltage
0.0 to
255.0
0.0 V A S - 30C 115
E2: Motor Parameters
Use E2 parameters to set motor-related data.
E2-01
Motor Rated
Current
Sets the motor nameplate full load current in
amperes (A).
Automatically set during Auto-Tuning.
10 to
200% of
drive
rated
current
<27>
<57> SS− 30E 116
E2-02
Motor Rated
Slip
Sets the motor rated slip in Hertz.
Automatically set during rotational
Auto-Tuning.
0.00 to
20.00
<57> AA− 30F 116
E2-03
Motor No-Load
Current
Sets the magnetizing current of the motor in
Ampere.
Automatically set during rotational
Auto-Tuning.
0 to less
than
E2-01
<57> AA− 310 117
No. Name Description Range Def.
Control
Mode
Addr.
Hex
Pg.
V/f
OL
V
PM
ACrms Out(V)
Frequency (Hz)
E1-09 E1-07 E1-06 E1-11 E1-04
E1-05
E1-12
E1-13
E1-08
E1-10