< 10. Spare Parts and Consumables >
10-1
IM 12F5A1-01E
10. SPAREPARTSANDCONSUMABLES
10.1 SparePartsandConsumablesList
Name PartNo. Description Q´ ty
Recommended
replacement interval*
Indicator Electrode (Rotating electrode) K9332MB Gold electrode 1 Yearly
Indicator Electrode (Rotating electrode) K9334JP Gold alloy indicator electrode 1 Yearly
Counter Electrode K9332MK Silver chloride electrode 1 At the time of damage
Ceramic Beads K9332ZP For cleaning general type indicator
electrode, 2 bags
1 Yearly
Glass Beads K9332ZJ For cleaning combined chlorine insensitive
type indicator electrode, 2 bags / 1Q' ty
1 Yearly
Polishing Powder (Alumina) K9088PE For polishing indicator electrode 1 -
Rotating Contact K9332SR Part for electrode mechanism block 1 Yearly
Fuse A1111EF 2A 1 Yearly (*1)
Driven Shaft Assembly K9334JV Part for electrode mechanism block 1 3 years
O-Ring Y9115XB Part for electrode mechanism block 1 3 years
Drive Belt L9804UK Part for electrode mechanism block 1 3 years
Motor Assembly (100 V) K9334JY Part for electrode mechanism block 1 3 years
Motor Assembly (110 V) K9334VQ Part for electrode mechanism block 1 3 years
Motor Assembly (200 V) K9334VR Part for electrode mechanism block 1 3 years
Motor Assembly (220 V) K9334VS Part for electrode mechanism block 1 3 years
GearHead(100V/110V) K9332JP Part for electrode mechanism block 1 3 years
GearHead(200V/220V) K9334VA Part for electrode mechanism block 1 3 years
Activated Charcoal Filter L9862AY For zero calibration 1 Yearly
(*1) Although Fuse may be used more than one year, we recommend periodical replace for planning maintenance.
10.2 SpareParts
10.2.1 PolishingPowder(K9088PE)
Used to remove contamination on the indicator electrode that cannot be removed by automatic
cleaning using glass beads (ceramic beads). One bag of abrasive is provided for the FC400G.
10.2.2 CeramicBeads(K9332ZP)
Used to replenish or replace the ceramic beads used for automatic cleaning of the indicator
electrodewhentheiramountdiminishesbelowthespeciedlevelortheircontaminationcanno
longerberemoved.Theamountofthebeadsforreplenishmentorreplacementdi󰀨erswiththe
FC400Goperatingconditions.Generally,approx.onetotwobagsofbeadsperyeararerequired.
One bottle of ceramic beads is provided for the FC400G.
Thesameappliestoglassbeads(K9332ZJ)usedin(todecreaseinuenceof)combined
chlorine insensitive version.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA FC400G and is the answer not in the manual?

YOKOGAWA FC400G Specifications

General IconGeneral
BrandYOKOGAWA
ModelFC400G
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals