<2. Screens>
2-6
IM 12A01G01-03EN 1st Edition : Mar. 25, 2021-00
2.2 Main screen
On Main screen, FLXA402T assigns sensor connection numbers to up to 4 measurements
respectively.
Main screen shows up upon startup when only one sensor connection (Sensor connection
number 1) is dened for display.
When more than two sensor connections are dened for display, tap a preferred sensor
connection number on Home screen, Main screen of the selected sensor connection appears.
You can switch the page by tapping .
To switch the displayed item from 1st item to 2nd item, tap the 2nd item on the Main screen. The
tapped item replaces itself with 1st item.
NOTE
You can program positions where every 1st to 3rd item to display (4.5.1 Display 1, 2, 3, 4
settings ) For instance, in pH measurement, by default, pH measurement value appears at the
position of 1st item (1st line) and temperature value goes to the one for 2nd item (2nd line.)
E
F
(3)
A
C D
G
(2)
(5)
(1)
B
(4)(6)
H
(8)(7)
Figure 2.6 Sample image of Main screen
A: 1st item measurement value (1st line)
B: 1st item unit (1st line)
C: Sensor connection number
*1
D: Display name (user programmable)
E: Additional text information of 1st item (Additional text 1)
F: 2nd item: measurement value (2nd line)
G: Status (on display only during the non-measurement state)
H: Contact output (lights on only when the contact is being excited)
(1) “Home screen”
(2) “Converter menu”
(3) Calibration
(4) Sensor menu
(5) Page switch (next/previous)
*2
(6) “Solvent Valve Manual switch”
(7) “Measurement electrode” (not on display for “-TB”: TB measurement)
Measurement electrode can be turned On/O󰀨. Press and a dialog appears to conrm the
operation.
(8) “Maintenance”
Shows the current status is Maintenance mode or not. Press to switch the mode.
*1 If a converter is assigned in place of sensor, is displayed. (See 4.5.1)
*2 If only one sensor connection is dened for display (1-1), this does not show up.