1-14
<Toc> < 1. Installation >
IM 05D01C02-41E 3rd Edition: May 31, 2006-00
UT550 Standard Type (Model: UT550-0
, UT550-2
or UT550-3
), Single-loop Control
1
2
3
4
5
6
7
8
9
10
41
42
43
44
45
46
47
48
49
50
31
32
33
34
35
36
37
38
39
40
21
22
23
24
25
26
27
28
29
30
11
12
13
14
15
16
17
18
19
20
8
9
Power supply
10
L
N
A
llowable range: 100-240 V AC (
10%)
(free voltage)
50/60 Hz shared
Power supply
12
13
TC input
11
12
RTD input
13
12
13
mV/V input
21
22
Remote input
*
Wiring can only be carried out for
controllers with remote input.
Specify in a range of
1-5 V DC, 0-2 V DC,
or 0-10 V DC.
23
24
RS-485 communication
* Wiring can only be carried out
for controllers with communication
functions.
Maximum baud rate: 9600 bps
25
26
27
SDB(+)
SDA(-)
RDB(+)
RDA(-)
SG
*
The functionality of a contact input can be varied by changing the setting of the contact
input registration parameter.
* Factory-set to PV retransmission.
* Retransmission output 1 is not available if a
15 V DC loop power supply is used.
24 V DC loop
power supply
*Wiring can only be carried out for controllers with
24 V DC loop power supply.
1
2
Relay contact output
3
Control output
NC
NO
COM
Contact rating: 250 V AC, 3 A
30 V DC, 3 A (resistance load)
*Time proportional PID relay contact
output is configured at factory
before shipment.
Note: Select this option from
the OT1 parameter.
CAUTION
Before carrying out wiring, turn off the power
to the controller and check that cables to be
connected are not alive with a tester or the like
because there is a possibility of electric shock.
A
b
B
-
+
-
+
-
+
21.6-28.0VDC
(30 mA DC max.)
43
44
+
-
Default: 1-5 V DC
OT1=0 (factory-set default) OT1=1
Correspondence between parameter OT1 and control output types
OT1=2
OT1=3
* OT1 is a setup parameter.
You can change the settings of the parameter OT1 to change the control output type.
See "2. Initial Settings".
.
Time proportional control
Relay output
(terminals , and )
1
2
3
Time proportional control
Voltage pulse output
(terminals and )
16
17
Current output
(terminals and )
16
17
On-off control
Relay output
(terminals , and )
1
2
3
PV input
* Not configured at factory before shipment
See "2. Initial Settings". .
19
18
External contact inputs
40
39
38
37
20
28
30
DI1
DI2
DI3
DI4
DI5
DI6
COM
COM
DI8
AUTO when DI1=ON
MAN when DI1=OFF
STOP when DI2=ON
RUN when DI2=OFF
DI3
DI4
1.SP2.SP3.SP4.SP
ON
ONOFF
OFF
ON
ON OFF
OFF
5.SP6.SP7.SP8.SP
ON
ONOFF
OFF
ON
ON OFF
OFF
DI5
DI6
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
Common
Remote when DI8=ON
Local when DI8=OFF
Common
When switching among target setpoints 1 to 8:
19
18
40
39
38
37
20
28
30
DI1
DI2
DI3
DI4
DI5
DI6
COM
COM
DI8
+5V
+5V
+5V
+5V
+5V
+5V
36
DI7
36
DI7
+5V
+5V
Contact Transistor contact
Contact rating: 12 V DC, 10 mA or more
No function
16
17
Current/voltage
pulse output
0-20mADC,
4-20mADC
Voltage pulse (12 V)
Control output
14
15
Retransmission output 1
*
4-20 or
0-20 mA DC
14
15
15 V DC loop power supply
*
14.5-18.0 V DC
(21 mA DC max.)
* Retransmission output 2 is available
only when relay is selected as the
type of control output.
16
17
Retransmission
output 2*
Default: 4-20 mA DC
Default: 4-20 mA DC
0-20mADC,
4-20mADC
UT
* If all of the contact inputs are set to OFF,
the controller uses the immediately
preceding target setpoint.
-
+
-
+
-
+
-
+
6
5
External contact outputs
4
7
34
33
DO1
DO2
DO3
COM
DO4
DO5
Relay Transistor
No function
Alarm 1 output
Alarm 2 output
Alarm 3 output
Common
Alarm 4 output
32
DO6
31
DO7
35
COM
No function
Common
UT
FAIL output
(ON when normal)
Relay contact rating: 240 V AC, 1 A
30 V DC, 1 A (resistance load)
Transistor contact rating: 24 V DC, 50 mA
Load resistance: 600
or less
12
13
Note: Connecting a 250
resistor to the terminals is
optional.
Model: X010-250-2 (resistor with M3.5 crimp-on terminal
lugs)
*
When receiving 4-20 mA DC current signals,
set the PV input type to 1-5 V DC (setpoint
41).
Receiving 4-20 mA DC Current
Signals with the Controller
250
4-20mA
-
+
Default: Unspecified
retransmission type
Note: Select this option from the OT1 parameter.
Note: External Contact Input
If the power is turned on when the external contact input is OFF, the mode (SPN, R/L, or A/M)
existing before the power is turned off will be continued. (except for RUN/STOP)
* When current / voltage value
is selected
as the type of control output, these can be
used for alarm 4 output.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA UT520 and is the answer not in the manual?

YOKOGAWA UT520 Specifications

General IconGeneral
BrandYOKOGAWA
ModelUT520
CategoryController
LanguageEnglish

Related product manuals