198 | Aprisa LTE User Manual
Action Threshold Criteria
This parameter sets the LTE event that will trigger the action output.
Option
Function
None
No action output.
Equal Critical
Activates the action output when an LTE alarm is critical
alarm
Equal Major
Activates the action output when an LTE alarm is a major
alarm
Equal Minor
Activates the action output when an LTE alarm is minor
alarm
Equal Warning
Activates the action output when an LTE alarm is a
warning alarm
Equal Cleared
Activates the action output when an LTE alarm is cleared
Equal or Worse than Major
Activates the action output when an LTE alarm is a major
alarm or a critical alarm
Equal or Worse than Minor
Activates the action output when an LTE alarm is a minor
alarm, a major alarm or a critical alarm
Equal or Worse than Warning
Activates the action output when an LTE alarm is a
warning, a major alarm, a minor alarm or a critical alarm
Controls
The Save button saves the current event action setup.
The Cancel button cancels the new event action setup.
The Clear Map button clears all alarm selections on the current setup.