52 | LTE Router Installation
Aprisa LTE User Manual 2.1
Cooling
If the Aprisa LTE is operated in an environment where the ambient temperature exceeds 50°C, the
convection air flow over the heat sink must be considered.
The environmental operating conditions are as follows:
Operating temperature
-30 to +70˚ C (-22 to +158˚ F)
Storage temperature
-40 to +85˚ C (-40 to +185˚ F)
Humidity
Maximum 95% non-condensing
WARNING:
If the Aprisa LTE is operated in an environment where the ambient temperature
exceeds 50°C, the Aprisa LTE must be installed within a restricted access location to
prevent human contact with the enclosure heat sink.
ATTENTION:
Si l’Aprisa LTE fonctionne dans un environnement où la température ambiante dépasse
50 ° C, l’Aprisa LTE doit être installé dans un endroit à accès restreint de manière à
éviter tout contact humain avec le dissipateur de chaleur du boîtier.
WARNING:
The Aprisa LTE can be operated in an environment where the ambient temperature
exceeds 50°C. The heat sink will be a hot surface - do not touch.
ATTENTION:
L'Aprisa LTE peut fonctionner dans un environnement la température ambiante
dépasse 50 ° C. Le dissipateur de chaleur sera une surface chaude - ne le touchez pas.