System Functions and Features as of I7.9
290 Call logging (CL)
syd-0200/3.0 – I7.9 – 11.2009
The page header
can be suppressed with the setting ..._OCL page length = 99.
Output every time at the beginning of each page.
Contains only formatting, no user data.
User data appears on the next line.
Example:
(see "Example of Protocol format", page 291)
Data lines
Tab. 117 Data lines for protocol format
'Underline ''—..— '74 2
Line 2 end CR 1 75
New line LF 1 76
Content, meaning Structure Format
Lengt
h
Print
offset
Space SP 2 0
User (cost centre) number
1)
1)
Dialling determines whether user No. or CC No. is displayed. With exchange access 0 or 10, the user No. is
displayed; if exchange access is used with CC No. 13 or if there is a switch to the cost centre during the call
using *78, the CC No. is displayed. User numbers are always output with format "|- SP"; cost centre numbers,
always with format "00 -|".
As a cost centre number this field can be 5 or 9 digits long. Depending on the configured cost centre length
≤ 5, the field is 5 characters long. As of cost centre length ≥ 6, the length is 9 characters. With cost centre
length ≥ 6, all the offsets following the cost centre are incremented by 4 characters.
ttttt |- SP 5 2
Sort character ooo 00 -| 3 8
Date of start of connection ddmmyy 00 -| 6 12
Time of start of connection hh:mm 00 -| 5 19
Duration of connection hhHmmMss 00 -| 8 25
Trunk card number / network interface number /
primary channel group
2)
bb.pp/c 00 -| 5 34
Charges ggggggg.gg SP -| 10 40
Call number dialled
3)
zzzzzzzzzzzzzzzzzzzz |- SP 20 51
Serial number llll 00 -| 4 72
Carriage Return CR 1 76
Line Feed LF 1 77
Content, text Structure Length Print offset