System Functions and Features as of I7.9
296 Call logging (CL)
syd-0200/3.0 – I7.9 – 11.2009
7. 7. 7. 1 PC1 format
This format covers requirements for direct transfer to a PC (PC1).
Format structure
Tab. 123 PC1 format
Data field, meaning Structure Format
Lengt
h
Offset
Start of data record HT 1 0
User (cost centre) number
1)
1)
Dialling determines whether user No. or CC No. is displayed.
As a cost centre number this field can be 5 or 9 digits long. Depending on the configured cost centre length
≤ 5, the field is 5 characters long. As of cost centre length ≥ 6, the length is 9 characters. With cost centre
length ≥ 6, all the offsets following the cost centre are incremented by 4 characters.
ttttt I- SP 5 1
Sort character oo 00 -I 2 17
Date yymmdd 00 -I 6 10
Start time hh:mm 00 -I 5 17
Duration of connection hhHmmMss 00 -I 8 23
Primary channel group / trunk card number / net-
work interface number
2)
2)
The primary channel group is output in position "c", the trunk card number in position "bb" and the network
interface number in position "pp" (see example on page 292).
cbbpp 00 -I 5 32
Number of metering pulses iiiii 00 -I 5 38
Call number dialled
3)
3)
If Data protection is configured, the last 4 digits of the number are replaced by the space character "SP".
zzzzzzzzzzzzzzzzzzzz I- SP 20 44
Serial number llll 00 -I 4 65
Carriage Return CR 1 69
Line Feed LF 1 70