Electrical power network specification
Input voltage range 3~ 380…480 V AC. This is indicated in the
type designation label as typical input voltage levels 3~ 400/480
V AC.
Voltage (
U
1
)
Public low voltage networks. TN (grounded), IT (ungrounded)
and corner-grounded TN systems. See section Checking the
compatibility with IT (ungrounded) and corner-grounded TN
systems (page 85).
Network type
65 kA when protected by fuses given in the fuse tablesRated conditional short-
circuit current (IEC 61439-
1)
47 to 63 HzFrequency
Max. ± 3% of nominal phase to phase input voltageImbalance
0.98 (at nominal load)Fundamental power factor
(cos phi
1
)
Motor connection data
Asynchronous AC induction motorMotor types
0.…500 HzFrequency
0.01 HzFrequency resolution
See section Ratings (page 139).
Current
2 kHz, 4 kHz, 8 kHz, 12 kHz (depends on the frame and parameter
settings)
Switching frequency
Technical data 153