300 Parameters
46.33 Above torque limit Defines the trigger level for “above limit” indication in torque
control. When actual torque exceeds the limit, bit 10 of 06.17
Drive status word 2 is set.
300.0%
0.0…1600.0% “Above limit” indication trigger level for torque control. See par.
46.03
46.41 kWh pulse scaling Defines the trigger level for the “kWh pulse” on for 50 ms. The
output of the pulse is bit 9 of 05.22 Diagnostic word 3.
1.000 kWh
0.001…
1000.000 kWh
“kWh pulse” on trigger level. 1 = 1 kWh
47
47 Data storage
Data storage parameters that can be written to and read from
using other parameters’ source and target settings.
Note that there are different storage parameters for different
data types.
See also section Data storage parameters (page 139).
47.01 Data storage 1
real32
Data storage parameter 1. 0.000
-2147483.000…
2147483.000
32-bit data. -
47.02 Data storage 2
real32
Data storage parameter 2. 0.000
-2147483.000…
2147483.000
32-bit data. -
47.03 Data storage 3
real32
Data storage parameter 3. 0.000
-2147483.000…
2147483.000
32-bit data. -
47.04 Data storage 4
real32
Data storage parameter 4. 0.000
-2147483.000…
2147483.000
32-bit data. -
47.11 Data storage 1
int32
Data storage parameter 9. 0
-2147483648…
2147483647
32-bit data. -
47.12 Data storage 2
int32
Data storage parameter 10. 0
-2147483648…
2147483647
32-bit data. -
47.13 Data storage 3
int32
Data storage parameter 11. 0
-2147483648…
2147483647
32-bit data. -
47.14 Data storage 4
int32
Data storage parameter 12. 0
-2147483648…
2147483647
32-bit data. -
47.21 Data storage 1
int16
Data storage parameter 17. 0
-32768…32767 16-bit data. 1 = 1
No. Name/Value Description Def/FbEq16
ACS580 FW.book Page 300 Wednesday, September 21, 2016 9:48 PM