368 Additional parameter data
43.09 Brake resistor Pmax cont Real 0.00…10000.00 kW 100 = 1 kW
43.10 Brake resistance Real 0.0…1000.0 ohm 10 = 1 ohm
43.11 Brake resistor fault limit Real 0…150 % 1 = 1%
43.12 Brake resistor warning limit Real 0…150 % 1 = 1%
44 Mechanical brake control
44.01 Brake control status PB 0000h…FFFFh - 1 = 1
44.06 Brake control enable Binary
src
--1 = 1
44.08 Brake open delay Real 0.00…5.00 s 100 = 1 s
44.13 Brake close delay Real 0.00…60.00 s 100 = 1 s
44.14 Brake close level Real 0.00…1000.00 rpm 100 = 1 rpm
45 Energy efficiency
45.01 Saved GW hours Real 0…65535 GWh 1 = 1 GWh
45.02 Saved MW hours Real 0…999 MWh 1 = 1 MWh
45.03 Saved kW hours Real 0.0…999.9 kWh 10 = 1 kWh
45.04 Saved energy Real 0.0…214748364.0 kWh 10 = 1 kWh
45.05 Saved money x1000 Real 0…4294967295 thousands (defina-
ble)
1 = 1 currency
unit
45.06 Saved money Real 0.00…999.99 (defina-
ble)
100 = 1
currency unit
45.07 Saved amount Real 0.00…21474830.08 (defina-
ble)
100 = 1
currency unit
45.08 CO2 reduction in kilotons Real 0…65535 metric
kiloton
1 = 1 metric
kiloton
45.09 CO2 reduction in tons Real 0.0…999.9 metric
ton
10 = 1 metric
ton
45.10 Total saved CO2 Real 0.0…214748300.8 metric
ton
10 = 1 metric
ton
45.11 Energy optimizer List 0…1 - 1 = 1
45.12 Energy tariff 1 Real 0.000…4294966.296 (defina-
ble)
1000 = 1
currency unit
45.13 Energy tariff 2 Real 0.000…4294966.296 (defina-
ble)
1000 = 1
currency unit
45.14 Tariff selection Binary
src
--1 = 1
45.18 CO2 conversion factor Real 0.000…65.535 tn/ MWh 1000 = 1
tn/MWh
45.19 Comparison power Real 0.00…10000000.00 kW 10 = 1 kW
45.21 Energy calculations reset List 0…1 - 1 = 1
46 Monitoring/scaling settings
46.01 Speed scaling Real 0.00…30000.00 rpm 100 = 1 rpm
46.02 Frequency scaling Real 0.10…1000.00 Hz 100 = 1 Hz
46.03 Torque scaling Real 0.1…1000.0 % 10 = 1%
No. Name Type Range Unit FbEq32
ACS580 FW.book Page 368 Wednesday, September 21, 2016 9:48 PM