36 Control panel
Remote The drive is in remote control, ie, controlled through I/O or fieldbus.
The icons in the top pane indicate which actions are allowed with the control
panel:
2. Panel bus: Indicates that there are more than one drive connected to this panel.
To switch to another drive, go to Options - Select drive.
3. Status icon: Indicates the status of the drive and the motor. The direction of the
arrow indicates forward (clockwise) or reverse (counter-clockwise) rotation
4. Drive name: If a name has been given, it is displayed in the top pane. By default,
it is “ACS580”. You can change the name on the control panel by selecting Menu
- Primary settings - Clock, region, display (see page 53).
5. Reference value: Speed, frequency, etc. is shown with its unit. For information on
changing the reference value in the Primary settings menu (see page 44).
6. Content area: The actual content of the view is displayed in this area. The
content varies from view to view. The example view on page 35 is the main view
of the control panel which is called the Home view.
7. Softkey selections: Displays the functions of the softkeys (
and ) in a
given context.
8. Clock: The clock displays the current time. You can change the time and time
format on the control panel by selecting Menu - Primary settings - Clock,
region, display (see page 53).
You can adjust the display contrast and back light functionality on the control panel by
selecting Menu - Primary settings - Clock, region, display (see page 53).
Text/Icons Starting from this
control panel
Stopping from this
control panel
Giving reference
from this panel
Remote
Not allowed Not allowed Not allowed
Remote
Allowed Allowed Not allowed
Remote
Not allowed Allowed Allowed
Remote
Allowed Allowed Allowed
Status icon Animation Drive status
-
Stopped
- Stopped, start inhibited
Blinking Stopped, start command given but start inhibited. See
Menu - Diagnostics on the control panel
Blinking Faulted
Blinking Running, at reference, but the reference value is 0
Rotating Running, not at reference
Rotating Running, at reference