Fans
The lifespan of the cooling fans of the drive depends on running time, ambient
temperature and dust concentration. See the firmware manual for the actual signal
which indicates the running time of the cooling fan. Reset the running time signal
after fan replacement.
Replacement fans are available from ABB. Do not use other than ABB-specified spare
parts.
■
Replacing a supply module (D7T) cooling fan
WARNING!
Obey the safety instructions of the drive. If you ignore them, injury or
death, or damage to the equipment can occur. If you are not a qualified
electrical professional, do not do installation, commissioning or
maintenance work.
Note: Before you start replacing the fan kit of the converter module, make sure that
the connector at the end of the fan kit cable is compatible with the counterpart in the
module. Black connector is compatible only with the black counterpart, and gray
connector only with the gray counterpart. If the connectors are not compatible, replace
the connector at the end of the fan kit cable. Use the connector in the old fan kit, or
order suitable connector from ABB.
1. Stop the drive and do the steps in section Electrical safety precautions (page 21)
before you start the work.
2. Open the cubicle door.
3. Remove the lower support bracket (a) of the module.
4. Remove the front cover of the fan holder (b).
5. Disconnect the fan wiring from the module: power supply plug and fibre optic
cables (c).
6. Support the fan holder (d) from below and pull it to release it from the module.
7. Pull out the fan holder.
8. Transfer the fan control box (e) from the old fan holder to the new fan holder.
9. Install the fan holder in reverse order to the above.
186 Maintenance