Parameters 181
07.21 Application
environment status
1
(Only visible with option +N8010 [application
programmability])
Shows which tasks of the application program are running.
See the Drive (IEC 61131-3) application programming
manual (3AUA0000127808 [English]).
-
0000h…FFFFh Application program task status. 1 = 1
07.22 Application
environment status
2
(Only visible with option +N8010 [application
programmability])
Shows the status of the openings in the application program.
See the Drive (IEC 61131-3) application programming
manual (3AUA0000127808 [English]).
-
0000h…FFFFh Application program opening status. 1 = 1
07.23 Application name (Only visible with option +N8010 [application
programmability])
First five ASCII letters of the name given to the application
program in the programming tool. The full name is visible
under System info on the control panel or the Drive composer
PC tool.
_N/A_ = None.
-
07.24 Application version (Only visible with option +N8010 [application
programmability])
Application program version number given to the application
program in the programming tool. Also visible under System
info on the control panel or the Drive composer PC tool.
-
07.25 Customization
package name
First five ASCII letters of the name given to the customization
package. The full name is visible under System info on the
control panel or the Drive composer PC tool.
_N/A_ = None.
-
07.26 Customization
package version
Customization package version number. Also visible under
System info on the control panel or the Drive composer PC
tool.
-
No. Name/Value Description Def/FbEq16
Bit Name Description
0 Pre task 1 = Pre-task running.
1 Appl task1 1 = Task 1 running.
2 Appl task2 1 = Task 2 running.
3 Appl task3 1 = Task 3 running.
4…14 Reserved
15 Task monitoring 1 = Task monitoring enabled.
Bit Name Description
0 Opening1 Status of opening 1 in the application program.
1 Opening2 Status of opening 2 in the application program.
……
15 Opening16 Status of opening 16 in the application program.