Additional parameter data 533
35.54 Motor nominal temperature
rise
Real 0…300 °C or 32…572 °F °C or °F 1 = 1°
35.55 Motor thermal time constant Real 100…10000 s 1 = 1 s
35.60 Cable temperature Real 0.0 200.0 % 10 = 1%
35.61 Cable nominal current Real 0.00 10000.0 A 100 = 1 A
35.62 Cable thermal rise time Real 0…50000 s 1 = 1 s
35.100 DOL starter control source Binary
src
--1 = 1
35.101 DOL starter on delay Real 0…42949673 s 1 = 1 s
35.102 DOL starter off delay Real 0…715828 min 1 = 1 min
35.103 DOL starter feedback source Binary
src
--1 = 1
35.104 DOL starter feedback delay Real 0…42949673 s 1 = 1 s
35.105 DOL starter status word PB 0000b…1111b - 1 = 1
35.106 DOL starter event type List 0…2 - 1 = 1
36 Load analyzer
36.01 PVL signal source Analog
src
--1 = 1
36.02 PVL filter time Real 0.00 … 120.00 s 100 = 1 s
36.06 AL2 signal source Analog
src
--1 = 1
36.07 AL2 signal scaling Real 0.00 … 32767.00 - 100 = 1
36.09 Reset loggers List 0…3 - 1 = 1
36.10 PVL peak value Real -32768.00 … 32767.00 - 100 = 1
36.11 PVL peak date Data --1 = 1
36.12 PVL peak time Data --1 = 1
36.13 PVL current at peak Real -32768.00 … 32767.00 A 100 = 1 A
36.14 PVL DC voltage at peak Real 0.00 … 2000.00 V 100 = 1 V
36.15 PVL speed at peak Real -32768.00 … 32767.00 rpm 100 = 1 rpm
36.16 PVL reset date Data --1 = 1
36.17 PVL reset time Data --1 = 1
36.20 AL1 below 10% Real 0.00 … 100.00 % 100 = 1%
36.21 AL1 10 to 20% Real 0.00 … 100.00 % 100 = 1%
36.22 AL1 20 to 30% Real 0.00 … 100.00 % 100 = 1%
36.23 AL1 30 to 40% Real 0.00 … 100.00 % 100 = 1%
36.24 AL1 40 to 50% Real 0.00 … 100.00 % 100 = 1%
36.25 AL1 50 to 60% Real 0.00 … 100.00 % 100 = 1%
36.26 AL1 60 to 70% Real 0.00 … 100.00 % 100 = 1%
36.27 AL1 70 to 80% Real 0.00 … 100.00 % 100 = 1%
36.28 AL1 80 to 90% Real 0.00 … 100.00 % 100 = 1%
36.29 AL1 over 90% Real 0.00 … 100.00 % 100 = 1%
36.40 AL2 below 10% Real 0.00 … 100.00 % 100 = 1%
36.41 AL2 10 to 20% Real 0.00 … 100.00 % 100 = 1%
No. Name Type Range Unit FbEq32