48 ESP program features
Current pulse-start
Current pulse-start function enables when regular starting routines are not enough to
accelerate the motor. The most common reason can be pump waxing or
sedimentation. The function produces a series of thrusts to the pump impeller by
sending short high-current impulses.
You can adjust speed, magnitude and frequency of thrusts applied. After the Current
pulse-start routine is competed, the control is given to Kick-start function (if enabled)
and then proceed to production speed with additional help of the acceleration
assistance (if enabled).
Settings
Parameter group 75 ESP reference setup (page 421).
Speed reference
75.61 Current pulse
speed reference
75.15 Starting speed
75.62 Current pulse
start current ref
Time
Time
0
0
Regular current
Pulse-start cycle 1
Pulse-start cycle 2
Last cycle
75.69 Current pulse
cycle time
75.69 Current pulse
cycle time