Additional parameter data 553
79.58 Overload curve scale coef Real -30.000...30.000 - 1000 = 1
79.59 Overload curve offset Real -30000.00...30000.00 - 100 = 1
79.61 Overload recovery speed Real 0.00...600.00 Hz 100 = 1Hz
79.62 Overload recovery speed time Real 0.0...30000.0 s 10 = 1s
79.80 Underload actual limit Real -30000.00...30000.00 - 100 = 1
79.81 Underload trip count down Real 0.0...30000.0 s 10 = 1
79.89 URT recovery attempts Real 0...100 - -
79.90 Overload actual limit Real -30000.00...30000.00 - -
79.91 Overload trip count down Real 0.0...30000.0 s 10 = 1
79.99 Load protection status word PB 0b0000…0b1111 1111 1111
1111
--
80 Voltage control
80.01 Energy optimization enable List ---
80.10 U/F Curve enable List ---
80.11 Frequency point 1 Real 2.00...600.00 Hz 100 = 1Hz
80.12 Frequency point 2 Real 2.00...600.00 Hz 100 = 1Hz
80.13 Frequency point 3 Real 2.00...600.00 Hz 100 = 1Hz
80.14 Frequency point 4 Real 2.00...600.00 Hz 100 = 1Hz
80.15 Frequency point 5 Real 2.00...600.00 Hz 100 = 1Hz
80.16 Frequency point 6 Real 2.00...600.00 Hz 100 = 1Hz
80.17 Frequency point 7 Real 2.00...600.00 Hz 100 = 1Hz
80.18 Frequency point 8 Real 2.00...600.00 Hz 100 = 1Hz
80.21 Additive voltage 1 Real -100.00...100.00 % 100 = 1%
80.22 Additive voltage 2 Real -100.00...100.00 % 100 = 1%
80.23 Additive voltage 3 Real -100.00...100.00 % 100 = 1%
80.24 Additive voltage 4 Real -100.00...100.00 % 100 = 1%
80.25 Additive voltage 5 Real -100.00...100.00 % 100 = 1%
80.26 Additive voltage 6 Real -100.00...100.00 % 100 = 1%
80.27 Additive voltage 7 Real -100.00...100.00 % 100 = 1%
80.28 Additive voltage 8 Real -100.00...100.00 % 100 = 1%
80.31 Validate tuning cmd List ---
80.32 Voltage tuner source List ---
80.40 IR compensation enable List ---
80.41 IR compensation ref Real 0.00...50.00 % 100 = 1%
80.42 Step up frequency Real 2.00...300.00 Hz 100 = 1Hz
80.80 Flux correction Real -100.00...100.00 % 100 = 1%
80.81 Flux reference Real 0.00...200.00 % 100 = 1%
80.82 Actual additive voltage Real -100.00...100.00 % 100 = 1%
No. Name Type Range Unit FbEq32