184 Parameters
-600.00...600.00 Hz ESP frequency. 10 = 1Hz
09.22 Speed reference % Displays ESP speed/frequency reference in percent scale. 0.00
-1200.00
...1200.00 %
Speed reference. 10 = 1%
09.23 Speed reference
used
Displays the speed reference currently produced by the ESP
control program.
0.0
-30000.0...
30000.0 rpm
Speed reference. 10 = 1rpm
09.41 Restart delay
remaining
Displays the time remaining before restart delay function
stops inhibiting the user start command.
0.0
0.0...30000.0 min Restart delay time. 10 = 1min
09.48 ON-time remaining Displays the time remaining before ON-cycle is complete.
This is valid only when time control function is active.
0.0
0.0...30000.0 min Remaining ON time in minutes. 10 = 1min
09.49 OFF-time remaining Displays the time remaining before OFF-cycle is complete.
This is valid only when time control function is active.
0.0
0.0...30000.0 min Remaining OFF time in minutes. 10 = 1min
10
10 Standard DI, RO
Configuration of digital inputs and relay outputs.
10.01 DI status Displays the electrical status of digital inputs DIIL and
DI6…DI1. The activation/deactivation delays of the inputs (if
any are specified) are ignored. A filtering time can be defined
by parameter 10.51 DI filter time.
Bits 0…5 reflect the status of DI1…DI6; bit 15 reflects the
status of the DIIL input. Example: 1000000000010011b =
DIIL, DI5, DI2 and DI1 are on, DI3, DI4 and DI6 are off.
This parameter is read-only.
-
0000h…FFFFh Status of digital inputs. 1 = 1
10.02 DI delayed status Displays the status of digital inputs DIIL and DI6…DI1. This
word is updated only after activation/deactivation delays (if
any are specified).
Bits 0…5 reflect the delayed status of DI1…DI6; bit 15
reflects the delayed status of the DIIL input.
This parameter is read-only.
-
0000h…FFFFh Delayed status of digital inputs. 1 = 1