190 Parameters
10.28 RO2 ON delay Defines the activation delay for relay output RO2. 0.0 s
(95.20 b3)
t
On
= 10.28 RO2 ON delay
t
Off
= 10.29 RO2 OFF delay
0.0 3000.0 s Activation delay for RO2. 10 = 1 s
10.29 RO2 OFF delay Defines the deactivation delay for relay output RO2. See
parameter 10.28 RO2 ON delay.
0.0 s
(95.20 b3)
0.0 3000.0 s Deactivation delay for RO2. 10 = 1 s
10.30 RO3 source Selects a drive signal to be connected to relay output RO3.
For the available selections, see parameter 10.24 RO1
source.
Fault (-1)
10.31 RO3 ON delay Defines the activation delay for relay output RO3. 0.0 s
t
On
= 10.31 RO3 ON delay
t
Off
= 10.32 RO3 OFF delay
0.0 3000.0 s Activation delay for RO3. 10 = 1 s
10.32 RO3 OFF delay Defines the deactivation delay for relay output RO3. See
parameter 10.31 RO3 ON delay.
0.0 s
0.0 3000.0 s Deactivation delay for RO3. 10 = 1 s
10.51 DI filter time Defines a filtering time for parameter 10.01 DI status. 10.0 ms
0.3 100.0 ms Filtering time for 10.01. 10 = 1 ms
No. Name/Value Description Def/FbEq16
1
0
1
0
t
On
t
Off
t
On
t
Off
Status of selected
source
RO status
Time
1
0
1
0
t
On
t
Off
t
On
t
Off
Status of selected
source
RO status
Time