Parameters 413
62.32 Follower node 3
data 2 value
Displays, in integer format, the data received from the second
follower (ie. follower with node address 3) as word 2.
Parameter 62.08 Follower node 3 data 2 sel can be used to
select a target for the received data. This parameter can also
be used as a signal source by other parameters.
0
0…65535 Data received as word 2 from follower with node address 3.
62.33 Follower node 3
data 3 value
Displays, in integer format, the data received from the second
follower (ie. follower with node address 3) as word 3.
Parameter 62.09 Follower node 3 data 3 sel can be used to
select a target for the received data. This parameter can also
be used as a signal source by other parameters.
0
0…65535 Data received as word 3 from follower with node address 3.
62.34 Follower node 4
data 1 value
Displays, in integer format, the data received from the third
follower (ie. follower with node address 4) as word 1.
Parameter 62.10 Follower node 4 data 1 sel can be used to
select a target for the received data. This parameter can also
be used as a signal source by other parameters.
0
0…65535 Data received as word 1 from follower with node address 4.
62.35 Follower node 4
data 2 value
Displays, in integer format, the data received from the third
follower (ie. follower with node address 4) as word 2.
Parameter 62.11 Follower node 4 data 2 sel can be used to
select a target for the received data. This parameter can also
be used as a signal source by other parameters.
0
0…65535 Data received as word 2 from follower with node address 4.
62.36 Follower node 4
data 3 value
Displays, in integer format, the data received from the third
follower (ie. follower with node address 4) as word 3.
Parameter 62.12 Follower node 4 data 3 sel can be used to
select a target for the received data. This parameter can also
be used as a signal source by other parameters.
0
0…65535 Data received as word 3 from follower with node address 4.
62.37 M/F communication
status 1
In the master, displays the status of the communication with
followers specified by parameter 60.19 M/F comm
supervision sel 1.
In a follower, bit 0 indicates the status of the communication
with the master.
-
0000h…FFFFh M/F communication status (followers 1…16). 1 = 1
No. Name/Value Description Def/FbEq16
Bit Name Description
0 Follower 1 1 (in the master) = Communication with follower 1 OK.
1 (in a follower) = Communication with master OK.
1 Follower 2 1 = Communication with follower 2 OK.
……
15 Follower 16 1 = Communication with follower 16 OK.