Opening the connector interface plate
Notice that the procedure differs depending on if the connector interface is located
either at the rear or at the bottom of the base.
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
Valid for cabling with rear inter-
face
Remove the connector interface plate attachment
screws and carefully open the plate.
CAUTION
There are cabling attached to the plate. The plate
cannot be removed completely until the connect-
ors are removed.
2
xx2000001558
Valid for cabling with bottom inter-
face (option 3309-1)
xx2000001575
Disconnecting the earth cable
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
Continues on next page
Product manual - CRB 1300 227
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the cable package
Continued