Pulling out the cable package
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx2000001564
Remove the axis-1 connector plate.2
Wrap the connectors with the masking tape.3
xx2000001563
Pull out the cable package in the direction as
shown in the figure.
Note
Slip out the cable protectors while pulling out the
cable package.
4
Slip out the cable protectors.5
Refitting the cable package
Use these procedures to refit the cable package.
Securing the cable package in the base
NoteAction
Wrap the connectors with the masking tape.1
Continues on next page