Refitting the base covers
NoteAction
Gasket for base adapter:
3HAC067818-001
For robots with protection class IP67 (option
3350-670)
1
xx2000002510
Valid for cabling with rear interface
Check the gasket.
Replace if damaged.
Screw: M4x10 12.9 Lafre
2C2B/FC6.9 (8 pcs)
Valid for cabling with rear interface
Refit the base bottom cover together with the base
adapter.
2
Tightening torque: 2.6 Nm
xx2000001642
Securing the base to the foundation
NoteAction
Attachment screws: M16x50, qual-
ity: 8.8.
Secure the base to the foundation with the attach-
ment screws and washers.
1
Washers: 17 x 30 x 3, steel hard-
ness class 200HV.
Tightening Torque: 150 Nm±10
Nm.
Refitting the axis-1 mechanical stops
NoteAction
Screw: M4x25 12.9 Lafre
2C2B/FC6.9 (6 pcs)
Refit the axis-1 mechanical stop fixed block.1
Tightening torque: 3.8 Nm
xx2000001693