NoteAction
xx2000001604
Loosen the screws and move the motor slightly
to slacken the timing belt.
3
Remove the timing belt from its groove on the
motor.
4
xx2000001605
Remove the screws and washers.5
xx2000001669
Carefully lift out the motor.6
xx2000001670
Remove the timing belt.7
Removing the lower arm support
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
Continues on next page
Product manual - CRB 1300 391
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.5.2 Replacing the housing and extender unit