Removing the axis-3 gearbox
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
Removing gearboxes will release axes. This
means the axes can fall down.
Make sure axes are well supported before remov-
ing gearboxes.
2
xx2000001666
Remove the screws.3
xx2000001667
Pull out the gearbox.4
Separating the housing
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
Continues on next page
394 Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.5.2 Replacing the housing and extender unit
Continued