Refitting the extender unit
Note
Only CRB 1300-7/1.4 and have an extender unit, connecting the housing and
tubular.
Use these procedures to refit the extender unit before refitting the housing.
Refitting the extender unit
NoteAction
O-ring on tubular: 3HAC061327-
018
For robots with protection class IP67 (option
3350-670)
1
xx2000002519
Check the O-ring.
Replace if damaged.
Screw: M4x25 12.9 Lafre
2C2B/FC6.9 (12 pcs)
Refit the extender unit.2
Tightening torque: 3.8 Nm
xx2000001730
xx2000001731
Make sure that the notches on the extender unit
and tubular are aligned.
3
Continues on next page
398 Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.5.2 Replacing the housing and extender unit
Continued