EasyManua.ls Logo

ABB CRB 1300 - Page 413

ABB CRB 1300
726 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Securing the cable package in the housing
NoteAction
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (4 pcs)
Refit the axis-4 cable protector.1
Tightening torque: 2.6 Nm
xx2000001546
Reconnecting the axis-4 motor connectors
NoteAction
xx2000001545
Insert the male header of the motor connectors
to the connector plate.
1
xx2000001544
Reconnect the connectors.
FB4
MP4
Tip
See the number markings on the connectors for
help to find the corresponding connector.
2
xx2000001543
Route and secure the cabling with a cable strap.
Note
The motor cablings have another strap fixed. Pay
attention to the location where the new strap to
be fixed, see the figure as a guidance.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
Continues on next page
Product manual - CRB 1300 413
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.5.2 Replacing the housing and extender unit
Continued

Table of Contents

Related product manuals