Loading...
Removing the covers
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx2000001733
Remove the covers.
Tubular covers (A)
Housing cover (B)
Lower arm support cover (C)
2
Loosening the cables in the tubular
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx2000001530
Cut the cable straps.2
xx2000001531
Remove the connector plates.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate.
3
Continues on next page
424 Product manual - CRB 1300