Removing the axis-2 motor
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
WARNING
When separating the motor from the gearbox,
there may be pressure present in the gearbox,
causing lubricant to spray from the opening. Be-
fore proceeding, please read the safety informa-
tion in the section Gearbox lubricants (oil or
grease) on page 29.
2
CAUTION
Removing motors will release axes. This means
the axes can fall down.
Make sure axes are well supported before remov-
ing motors.
3
xx2000001624
Cut the cable strap.4
xx2000001625
Remove the cable bracket.5
Wrap the connectors with the masking tape and
pull the motor cablings carefully down to the swing
from the lower arm.
6
Continues on next page