Disconnecting the axis-3 motor connectors
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx2000001548
Remove the connector plate.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate, as shown in following step.
2
xx2000001620
Cut the cable strap.3
xx2000001619
Disconnect the connectors.
• FB3
• MP3
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
4
xx2000001621
Snap loose and remove the male head of the
connectors from the connector plate.
5
Continues on next page
Product manual - CRB 1300 511
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.6.3 Replacing the axis-3 motor
Continued