Removing the axis-3 timing belt
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
Loosening timing belts will release axes. This
means the axes can fall down.
Make sure axes are well supported before
loosening timing belts.
2
CAUTION
The upper arms, which includes housing, extender
unit (only for CRB 1300-7/1.4 and ), tubular and
tilt unit weighs 17 kg.
All lifting accessories used must be sized accord-
ingly!
3
Fit a roundsling to the upper arm to support the
weight (no force).
4
xx2000001614
Loosen the screws and move the motor slightly
to slacken the timing belt.
5
xx2000001615
Remove the timing belt from its groove on the
motor.
6
Continues on next page
512 Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.6.3 Replacing the axis-3 motor