Refitting the housing
NoteAction
O-ring on tubular: 3HAC061327-
018
For robots with protection class IP67 (option
3350-670)
1
xx2000002519
Valid for CRB 1300-11/0.9 and CRB 1300-10/1.15
Check the O-ring.
Replace if damaged.
xx2000001721
Valid for CRB 1300-11/0.9 and CRB 1300-10/1.15
Refit the tubular to the housing.
2
xx2000001672
Valid for CRB 1300-7/1.4 and
Refit the extender unit to the housing.
3
Flange socket head screw with
glue: 3HAB3413-412, M4x12 12.9
Lafre 2C2B/FC6.9+PrO-COat111,
with NYPLAS glue (14 pcs)
Refit the screws.4
Tightening torque: 3.3 Nm
xx2000001671
Continues on next page
650 Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.7.4 Replacing the axis-4 gearbox
Continued