EasyManua.ls Logo

ABB CRB 1300 - Page 660

ABB CRB 1300
726 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NoteAction
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (4 pcs)
Refit the process hub.4
Tightening torque: 2.6 Nm
xx2200001000
Securing the cable package in the tubular
NoteAction
Screw: M4x12 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Refit the first semicircular bracket to fix the cable
package.
1
Tightening torque: 2.6 Nm
xx2000001748
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (2 pcs for each plate)
Refit the connector plate.2
Tightening torque: 1.3 Nm
xx2000001531
xx2000001530
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
Continues on next page
660 Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.7.4 Replacing the axis-4 gearbox
Continued

Table of Contents

Related product manuals