Parameters 415
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
SBC.22 SBC feedback
action
Sets the action that the FSO module takes
when there is a problem with the SBC
feedback.
No STO
STO The FSO module goes into the Fail-safe
mode and activates the drive STO function.
No STO The FSO module sends a warning to the
drive.
SBC.23 SBC test OK signal Sets the digital output that indicates the
status of the SBC test OK signal. Active
when the SBC feedback indicates that the
SBC works correctly.
Note: The feedback delay is 800 ms.
None
None No output connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7 Single output X113:7
DO X113:8 Single output X113:8
DO X113:9 Single output X113:9
DO X114:7 Single output X114:7
DO X114:8 Single output X114:8
DO X114:9 Single output X114:9
POUS
Parameters for the POUS function
POUS.01 POUS activity and
version
Activates or deactivates the POUS function
and shows the version of the POUS
function.
Disabled
Disabled Deactivates the POUS function.
Version 1 Activates version 1 of the POUS function.
POUS.02 POUS
acknowledgement
Sets the POUS acknowledgement method. Manual
Manual The FSO module reads the POUS
acknowledgement signal through the digital
input defined by parameter FSOGEN.42
Acknowledgement button input. The FSO
module accepts the acknowledgement after
the POUS request has been removed.
Automatic The FSO module generates the POUS
acknowledgement signal automatically after
the POUS request has been removed.
Index Name/Value Description Factory
default