416 Parameters
Safebus The FSO module expects an external POUS
acknowledgement signal from the safety
fieldbus after the POUS request has been
removed.
Manual_Safebus The FSO module expects an external POUS
acknowledgement signal either from a digital
input or from the safety fieldbus after the
POUS request have been removed.
POUS.11 POUS input Sets the digital input that is connected to the
POUS input.
None
None No input connected
DI X113:1 & X114:1 Redundant input X113:1 & X114:1
DI X113:2 & X114:2 Redundant input X113:2 & X114:2
DI X113:3 & X114:3 Redundant input X113:3 & X114:3
DI X113:4 & X114:4 Redundant input X113:4 & X114:4
DI X113:1 Single input X113:1
DI X113:2 Single input X113:2
DI X113:3 Single input X113:3
DI X113:4 Single input X113:4
DI X114:1 Single input X114:1
DI X114:2 Single input X114:2
DI X114:3 Single input X114:3
DI X114:4 Single input X114:4
POUS.13 POUS delay for
completion
Sets the delay for the activation of the POUS
complete indication after the POUS request.
0ms
0…3,600,000 ms Time
POUS.21 POUS output Sets the digital output that indicates the
activity of the POUS function. Active from
the POUS request until the function has
been acknowledged.
None
None No output connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7 Single output X113:7
DO X113:8 Single output X113:8
DO X113:9 Single output X113:9
DO X114:7 Single output X114:7
DO X114:8 Single output X114:8
DO X114:9 Single output X114:9
Index Name/Value Description Factory
default