Parameters 439
DI X114:4 Single input X114:4
Always on The SSM4 function is always on.
SSMx.42 SSM4 limit negative Sets the negative speed limit for the SSM4
function.
0.0 rpm
-35880.0 …0.0 rpm Speed
SSMx.43 SSM4 limit positive Sets the positive speed limit for the SSM4
function.
0.0 rpm
0.0…35880.0 rpm Speed
SSMx.44 SSM4 output Sets the digital output connected to the
SSM4 function. Active when the motor
speed is within the SSM4 speed limits.
None
None No output connected
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
DO X113:9 & X114:9 Redundant output X113:9 & X114:9
DO X113:7 Single output X113:7
DO X113:8 Single output X113:8
DO X113:9 Single output X113:9
DO X114:7 Single output X114:7
DO X114:8 Single output X114:8
DO X114:9 Single output X114:9
41
S_ENCGEN
General parameters for safety pulse encoders
S_ENCGEN.
01
Safe pulse encoder
version
Activates or deactivates the safety encoder
and shows the version of parameter group
S_ENCGEN and parameters FSOGEN.52
and SBC.14.
Disabled
Disabled Deactivates the safety pulse encoder.
Version 1 Activates the safety pulse encoder.
S_ENCGEN.
11
FSE diagnostic
failure reaction
Sets the action taken when there is a
problem with the FSE module or the safety
encoder.
STO
STO The FSO module goes into the Fail-safe
mode and activates the drive STO function.
No STO If there are no active safety functions, the
FSO module sends a warning to the drive. If
there are active safety functions, the FSO
module goes into the Fail-safe mode.
Index Name/Value Description Factory
default