Control elements and application parameter
Control element "Audio control"
Product manual 2CKA001473B5023
109
Value for pause:
Options: 0
1
The parameter is used to send the command of the pause button with "0" or "1".
- 1-byte value [0 - 255]: The value of a pause button is sent as 1-byte value without a
sign. The following supplementary parameter is available:
Value for pause:
Options: Setting option from 0 - 255
The parameter is used to send the value of the pause button as absolute value.
2.13.6 Use of stop button
Options: Deactivated
Activated
Deactivated: No stop button is enabled. No additional parameters available.
Activated: The stop button is enabled. The following supplementary parameter is available:
Object type stop button:
Options: 1 bit
1-byte value [0 - 255]
The parameter is used to specify the size of the communication object for sending
telegrams.
– 1 bit: Commands of a stop button are sent with 1 bit (0 or 1). The following
supplementary parameter is available:
Value for stop:
Options: 0
1
The parameter is used to send the command of the stop button with "0" or "1".
- 1-byte value [0 - 255]: The value of a stop button is sent as 1-byte value without a sign.
The following supplementary parameter is available:
Value for stop:
Options: Setting option from 0 - 255
The parameter is used to send the value of the stop button as absolute value.