4-34 Input / Output MN1941WEN
NextMove e100
connector
Pin Name of
signal
Function Connection on amplifier
(Note: connections may
be labeled differently)
X1 1 0 V Control supply ground
2 +24 V Control supply +24 V input
X12 9 REL NO Normally open relay contact
(closed to enable drive)
Drive Enable +
10 REL COM Common relay connection Drive Enable -
E1 / E2 Ethernet Ethernet / EPL communication E1 / E2
Table 3: Connector details for minimum system wiring shown in Figure 32