5-2 Operation MN1941WEN
5.1.2 Installing Mint WorkBench
The Windows user account requires administrative user rights to install Mint WorkBench.
5.1.2.1 To install Mint WorkBench from the CD (OPT-SW-001)
1. Insert the CD into the drive.
2. After a few seconds the setup wizard should start automatically. If the setup wizard does
not appear, select Run... from the Windows Start menu and type
d:\start
where d represents the drive letter of the CD device.
Follow the on-screen instructions to install Mint WorkBench.
5.1.2.2 To install Mint WorkBench from the website
To install Mint WorkBench from www.abbmotion.com, download the application and run it.
5.1.3 Starting the NextMove e100
If you have followed the instructions in the previous sections, you should have now
connected the power sources, inputs and outputs and the USB, serial, or Ethernet cable
linking the PC to the NextMove e100.
5.1.4 Preliminary checks
Before you apply power for the first time, it is very important to verify the following:
Disconnect the load from the motor until instructed to apply a load.
Inspect all power connections for accuracy, workmanship and tightness.
Verify that all wiring conforms to applicable codes.
Verify that the NextMove e100 is properly earthed/grounded.
Check all signal wiring for accuracy.
5.1.5 Power on checks
1. Turn on the 24 V DC control supply.
2. Within approximately 20-30 seconds or less, the test sequence should complete and the
Status LED should start to flash green. If the Status LED is not lit then re-check the
power supply connections. If the Status LED flashes red, this indicates that the
NextMove e100 has detected a fault - see section 6.