24 1SFC132003M0201
'HVFULSWLRQ
&KDSWHU
(QYLURQPHQWDOLQIOXHQFH
The product is designed to minimise the environmental
affects during manufacturing and use of the product. Most
of the materials used, are of recycle type and shall be
handled and recycled according to existing laws.
Further information regarding used material and recycling
of the product can be found at:
www.abb.com/lowvoltage
6SHFLILFDWLRQV
Degree of protection
(Main circuit)
IP 10 for PST30...72
IP 00 for PST85...1050
Vibration resistance According to LRS, Test 1
Operating position Vertical at
± 10°
Ambient temperature Storage: -25 °C to +70 °C (-13 °F to 158 °F)
Operation: 0
°C to +40 °C (32 °F to 104 °F
without derating
+40
°C to +50 °C (104 °F to 122 °F)
with derating 0,8% / °C (0,8%/ 33,8°F)
Altitude 1000 m (3281 ft.) above sea level without derating
1000 - 4000 m (3281 - 13123 ft.) with derating 0,8% /m
Pollution degree 3
Relative humidity 5 - 95% (non condensing)
EMC According to IEC 947-4-2 industrial networks
Immunity acc. to EN50082-2 (industrial equipment)
Spark test acc. to SS 4361503 (PL4)
Standards CE IEC 60947-4-2
Standards UL UL508