SMD17E2 SPECIFICATIONS
SMD17E2 User Manual
ADVANCED MICRO CONTROLS INC.
20
Status LED’s (continued)
Network Status (NS) LED
The Network Status LED is a bi-color red/green LED. The state of the LED depends on the protocol the
SMD17E2 is configured to for.
Table R1.4 Network Status LED States
SMD17E2 Connectors
Input Connector
As shown in figure R1.4, the Input Connector is located on the back of the
unit near its center. All digital input and power supply connections are
made at this connector. The connector is a standard five pin A-coded M12
connector that is rated to IP67 when the mate is properly attached. Figure
R1.5 shows the pinout of the connector when viewed from the back of the
SMD17E2.
Digital inputs are single ended and referenced to the DC Common pin.
(Sinking inputs.)
LED State EtherNet/IP Definition Modbus TCP Definition PROFINET Definition
Off No Power
No power or no TCP con-
nections
No power, duplicate IP
address on the network,
mismatch in Device Name,
or no connection to IO Con
-
troller.
Alternating
Red/Green
Power up Self-Test Power up Self-Test Power up Self-Test
Flashing
Green
Ethernet connection,
but no CIP connections
Indicates number of connec-
tions with 2 second delay
between group. The
SMD17E2 supports up to 5
concurrent connections.
On-line, Stop state. A con-
nection with the IO Control-
ler is established and it is in
its STOP state.
Steady Green
Valid Ethernet net-
work and CIP connec-
tions
Should not occur. LED
should always flash when
network is connected.
On-line, Run state. A con-
nection with the IO Control-
ler is established and it is in
its RUN state.
Flashing Red
MS LED steady green:
Network Connection
Timeout
Not Implimented Not Implimented
MS LED blinking green: IP Address or Network Protocol changed: Cycle power
Steady Red Duplicate IP address on network. Not Implimented.
Figure R1.4 SMD17E2
Connector Locations
PORT 2
POWER & INPUTS
MS
NS
PORT 1
Power: 24 to 48 Vdc
Figure R1.5 M12 Input Connector