SP 5801 2 clears most of the settings and counters stored in the NVRAM on the BICU (the values return to
their default values). However, the following settings are not cleared:
SP 5807 (Area Selection)
SP 5811 1 (Serial Num Input [Code Set])
SP 5811 3 (Serial Num Input [ID2 Code Display])
SP 5812 1 (Service TEL [Telephone])
SP 5812 2 (Service TEL [Facsimile])
SP 5907 (Plug & Play: Not used in this model)
SP 7 (Data Log)
SP 8 (History)
Use SP 5802 2 (basic machine) after you have replaced the BICU NVRAM or when the BICU NVRAM
data is corrupted. When the program ends normally, the message "Completed" shows.
- With Flash Memory Card
1. Upload the NVRAM data to a flash memory card ( NVRAM Data Upload/Download (SP
5824/5825)).
2. Print out all SMC data lists ( SMC Print (SP 5990)).
Be
sure to print out all the lists. You have to manually change the SP settings if the NVRAM data
upload ends abnormally.
3. Select SP 5801 2.
4. Press the OK key.
5. Select "Execute." The messages "Execute?" followed by "Cancel" and "Execute" shows.
6. Select "Execute."
7. When the program has ended normally, the message "Completed" shows. If the program has ended
abnormally, an error message shows.
8. Press the cancel key.
9. Turn the main switch off and on.
10. Download the NVRAM data from a flash memory card (
NVRAM Data Upload/Download (SP
5824/5825))
- Without Flash Memory Card -
1.
Print out all SMC data lists (
SMC Print (SP 5990)).
2.
Select SP 5-801.
3. Press the OK key.
4. Select "Execute." The messages "Execute?" followed by "Cancel" and "Execute" show.