3. Appendix: Troubleshooting Guide
Service Call Conditions
Summary
There are four levels of service call conditions.
Level Definition Reset Procedure
A
To prevent damage to the machine, the main machine
cannot be operated until the SC has been reset by a
service representative (see the note below).
Enter SP mode, and then turn the
main power switch off and on.
B
If the SC was caused by incorrect sensor detection, the
SC can be reset by turning the main power switch off
and on.
Turn the main power switch off and
on.
C
The main machine can be operated as usual, excluding
the unit related to the service call.
Turn the main power switch off and
on.
D
The SC history is updated. The machine can be
operated as usual.
The SC will not be displayed. Only
the SC history is updated.
If the problem concerns electrical circuit boards, first disconnect then reconnect the connectors before
replacing the PCBs.
If the problem concerns a motor lock, first check the mechanical load before replacing motors or
sensors.