2927* ID Sensor Control
2927 1
[0 = No / 1 = Yes]
Selects whether the ID sensor is or is not used for toner density control. This value should
normally be left at "1". If the value is "0", dirty background may occur after long periods
of non-use.
2928 Toner End Clear
2928 1
Clears the toner end condition without adding new toner. The following are cleared:
Toner end indicator (goes out)
Toner near-end counter
Toner near-end level
This function should generally not be used. If you clear the toner end condition without
adding new
toner, there is a risk that the drum may eventually begin to attract carrier after
many more copies are made and toner runs out. This attracted carrier may damage the
drum.
2929*
Vref Limits
Adjust the upper or lower Vref limit.
2929 1 Upper [0.50 to 3.50 / 3.20 / 0.01V/step] DFU
2929 2 Lower [0.50 to 3.50 / 0.70 / 0.01V/step] DFU
2994* ID Sensor Detection Temperature [30 to 90 / 30 / 1 °C/step]
2994 1
While the machine is recovering from an energy saver mode, or while the machine starts,
the BICU
ignores the ID-sensor signals if the fusing temperature is at the specified value or
higher.
2996* Transfer Roller Cleaning
2996 1
Selects whether the transfer roller is cleaned before each copy job. Set this to "1" if dirty
background is appearing on the reverse side of the first page of copy jobs. Note that this
will increase the time required to generate the first copy. If the setting is "0", the transfer
roller is never cleaned ( Transfer Roller Cleaning).
2998* Main Scan Magnification [–0.5 to +0.5 / 0.0 / 0.1%/step]
SP Mode Tables