A: Leading Edge Registration
B: Side-to-side Registration
- Blank Margin -
• If the leading edge or side-to-side registration cannot be adjusted to within the specification, then
adjust the leading-edge blank margin or the left-side blank margin.
1.
Check the trailing edge and right side edge blank margins, and adjust them using the following SP
modes.
SP mode Specification
Trailing edge SP 2101 2
2 +2.5/–1.5 mm
Right edge SP 2101 4
Leading edge SP 2101 1 2 ± 1.5 mm
Left edge SP 2101 3
4. Replacement and Adjustment
96