EasyManua.ls Logo

Agilent Technologies 1100 Series - User Manual

Agilent Technologies 1100 Series
214 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
A
Agilent 1100 Series
Diode Array and
Multiple Wavelength
Detector SL
User Manual

Table of Contents

Other manuals for Agilent Technologies 1100 Series

Questions and Answers

  • D
    Douglas NguyenSep 6, 2025
    What to do if Agilent Technologies Water Pump displays Electro-Magnetic-Proportional-Valve (EMPV) Missing?
    • D
      daguilarSep 6, 2025
      If the Agilent Technologies Water Pump displays 'Electro-Magnetic-Proportional-Valve (EMPV) Missing', ensure the connection cable is seated correctly. If the problem persists, the solenoid of the EMPV may be defective and should be replaced.
  • C
    Christopher SmithAug 25, 2025
    How to resolve leak sensor open error on Agilent Technologies Security Sensors?
    • D
      David HallAug 25, 2025
      If the Agilent Technologies Security Sensors system displays 'Leak Sensor Open', make sure the leak sensor is correctly connected. If it is, try replacing the leak sensor.
  • B
    Bryan WilsonAug 25, 2025
    Why Agilent Technologies Water Pump shows shutdown?
    • C
      Cameron WestAug 26, 2025
      The Agilent Technologies Water Pump may shut down due to several reasons: a leak detected in another module with a CAN connection (fix the leak before restarting), a leak or shut-down in an external instrument with a remote connection (check external instruments), or the degasser failing to generate sufficient vacuum (check the vacuum degasser for an error).
  • J
    Jennifer KirkSep 15, 2025
    What causes remote time-out in Agilent Technologies Security Sensors?
    • W
      William WrightSep 15, 2025
      If the Agilent Technologies Security Sensors unit reports a remote time-out, verify that the instrument showing the 'not-ready' condition is correctly installed and set up for analysis. Try exchanging the remote cable. If problems continue, check the instrument for defects, referring to its reference documentation.
  • P
    petersonjamesSep 23, 2025
    What to do if flow cell removed on Agilent Technologies Security Sensors?
    • T
      Thomas ChambersSep 23, 2025
      If the Agilent Technologies Security Sensors indicates 'Flow Cell Removed', insert the flow cell and turn on the lamp.
  • V
    Vincent DuncanSep 12, 2025
    Why Agilent Technologies Water Pump shows Unsupported Flow Sensor error?
    • B
      Brianna ThomasSep 12, 2025
      The 'Unsupported Flow Sensor' error on the Agilent Technologies Water Pump means that a 20 µl/min or a 100 µl/min flow sensor is being used with the nano pump. Change to the nano flow sensor to resolve this.
  • M
    Maria RussellSep 2, 2025
    Why Agilent Technologies Water Pump displays Zero Solvent Counter?
    • O
      ogreenSep 2, 2025
      If the Agilent Technologies Water Pump displays 'Zero Solvent Counter', it is because the volume in the bottle is below the specified volume or the limit is set incorrectly. Refill the bottles and reset the solvent counters.
  • L
    Lisa BlakeSep 2, 2025
    How to resolve Motor-Drive Power error on Agilent Technologies Water Pump?
    • S
      Scott BrownSep 2, 2025
      To resolve a 'Motor-Drive Power' error on the Agilent Technologies Water Pump, first ensure the capillaries and frits between the pump head and damper inlet are free from blockage. If the problem continues, the outlet ball valve may be blocked and should be replaced. High friction in the drive assembly can also cause this, so remove the pump head assembly to check for mechanical blockage. Finally, a defective drive assembly or CSM board might be the cause, requiring replacement.
  • E
    Erika StewartSep 22, 2025
    What causes ADC not calibrated error on Agilent Technologies Security Sensors?
    • L
      laurapowellSep 22, 2025
      If the Agilent Technologies Security Sensors unit displays 'ADC Not Calibrated', the ADC or other FLF electronics may be defective. Exchange the FLF board.
  • A
    Alexander DanielsAug 28, 2025
    How to fix Synchronization Lost on Agilent Technologies Water Pump?
    • W
      Wendy GarciaAug 28, 2025
      To fix a 'Synchronization Lost' error on the Agilent Technologies Water Pump, first ensure all CAN cables are correctly connected. If the problem persists, switch off and restart the system to determine which module is not recognized. A defective CAN cable can also cause this, so try replacing it. Also check that all CAN cables are installed correctly.

Summary

Site Requirements and Specifications

Site Requirements

Details on environmental conditions, power considerations, and power cords for detector operation.

Performance Specifications

Details on detection type, light source, wavelength range, noise, drift, and flow cell specifications.

Installing the Detector

Detector Installation Steps

Step-by-step instructions for physically installing the detector and connecting cables.

Flow Connections

Procedures for connecting the flow cell capillaries and tubing to the detector.

LAN Configuration

Initial LAN Setup Steps

Steps to note the MAC address and connect the instrument's LAN interface.

TCP;IP Parameter Configuration

Details on IP address, Subnet Mask, and Default Gateway configuration methods.

Link Configuration and Bootp Setup

Guidance on link speed/duplex settings and automatic configuration using Bootp.

Manual LAN Configuration

Procedures for manual configuration using Telnet or a Handheld Controller.

PC and ChemStation Setup

Steps to configure the PC and Agilent ChemStation for LAN communication.

Using the Detector

Running the Sample and Verification

Steps for running samples, verifying results, and obtaining chromatograms.

Detector Settings

Details on control, configuration, online spectra, analog outputs, spectrum, peakwidth, and slit settings.

How to Optimize the Detector

Optimizing Detector Performance

Introduction to optimizing detector parameters for signal and spectral data.

Troubleshooting and Diagnostics

Status Indicators Explained

Detailed explanation of the power supply and detector status indicators (green, yellow, red).

Maintenance and Repair

Warnings and Cautions

Essential safety warnings and precautions during maintenance and handling.

Maintenance

Exchanging the Lamp

Step-by-step guide for replacing the deuterium or tungsten lamp.

Exchanging a Flow Cell

Procedure for replacing the standard, semi-micro, or high-pressure flow cell.

Control Module Screens

Detector Diagnostics and Tests

Description of tests including intensity, wavelength calibration, and slit tests.

Appendix

General Safety Information

Comprehensive safety precautions for instrument operation, service, and repair.

Agilent Technologies 1100 Series Specifications

General IconGeneral
BrandAgilent Technologies
Model1100 Series
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals