1b-9
Operation Reference
Function
FLEX/FLEX-TD
Setting the data Rate and Pager Type
The parameter menu for the data rate and the pager type looks like the following:
DATA RATE specifies how fast the data stream is output in bits per second and whether it is
2-level or 4-level FSK.
1600/2: 1600 bps, 2-level FSK
3200/2: 3200 bps, 2-level FSK
3200/4: 3200 bps, 4-level FSK
6400/4: 6400 bps, 4-level FSK
PAGER TYPE specifies the type of message a pager under test can respond to and is selectable
from the following:
TONE ONLY: Short Message/Tone only type
NUMERIC: Numeric type
ALPHANUMERIC: Alphanumeric type
HEX/BIN: HEX/Binary type
If NUMERIC is selected, the next setting to be selected is VECTOR TYPE as shown:
VECTOR TYPE identifies the type of message as follows:
STANDARD: The pager-under-test displays the numeric message it receives.
SPECIAL: The pager-under-test converts the numeric message to a pre-defined message
which is displayed.
NUMBERED: The message numbers are assigned for each paging address separately
starting at 0 and progressing up to a maximum of 63 in consecutive order.