138 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide
9 Labels
Turning the Entry knob selects a character to enter into the highlighted
position shown in the "New label =" line above the softkeys and in the
Spell softkey. Labels can be up to ten characters in length.
4 Press the Enter softkey to enter the selected character and to go to the
next character position.
5 You may position the highlight on any character in the label name by
successively pressing the Enter softkey.
6 To delete a character from the label, press the Enter softkey until the
letter you want to delete is highlighted, then press the Delete Character
softkey.
7 When you are done entering characters for the label, press the
Apply New Label softkey to assign the label to the selected channel.
When you define a new label, it is added to the nonvolatile label list.
Label Assignment
Auto-Increment
When you assign a label ending in a digit, such as ADDR0 or DATA0, the
oscilloscope automatically increments the digit and displays the modified
label in the "New label" field after you press the Apply New Label softkey.
Therefore, you only need to select a new channel and press the Apply New
Label softkey again to assign the label to the channel. Only the original
label is saved in the label list. This feature makes it easier to assign
successive labels to numbered control lines and data bus lines.
To load a list of labels from a text file you create
It may be convenient to create a list of labels using a text editor, then
load the label list into the oscilloscope. This lets you type on a keyboard
rather than edit the label list using the oscilloscope's controls.
You can create a list of up to 75 labels and load it into the oscilloscope.
Labels are added to the beginning of the list. If more than 75 labels are
loaded, only the first 75 are stored.
To load labels from a text file into the oscilloscope:
1 Use a text editor to create each label. Each label can be up to ten
characters in length. Separate each label with a line feed.
2 Name the file labellist.txt and save it on a USB mass storage device
such as a thumb drive.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies InfiniiVision 3000 MSO-X 3012A and is the answer not in the manual?

Agilent Technologies InfiniiVision 3000 MSO-X 3012A Specifications

General IconGeneral
BrandAgilent Technologies
ModelInfiniiVision 3000 MSO-X 3012A
CategoryTest Equipment
LanguageEnglish

Related product manuals