264 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide
17 Save/Recall (Setups, Screens, Data)
Setup (*.scp) — The oscilloscope's horizontal timebase, vertical
sensitivity, trigger mode, trigger level, measurements, cursors, and
math function settings that tell the oscilloscope how to make a
particular measurement. See "To save setup files" on page 265.
8-bit Bitmap image (*.bmp) — The complete screen image in a reduced
color (8- bit) bitmap format. See "To save BMP or PNG image files" on
page 265.
24-bit Bitmap image (*.bmp) — The complete screen image in a 24- bit
color bitmap format. See "To save BMP or PNG image files" on
page 265.
24-bit image (*.png) — The complete screen image in a 24-bit color PNG
format that uses lossless compression. Files are much smaller than
the BMP format. See "To save BMP or PNG image files" on page 265.
CSV data (*.csv) — This creates a file of comma- separated values of all
displayed channels and math waveforms. This format is suitable for
spreadsheet analysis. See "To save CSV, ASCII XY, or BIN data
files" on page 266.
ASCII XY data (*.csv) — This creates separate files of comma- separated
values for each displayed channel. This format is also suitable for
spreadsheets. See "To save CSV, ASCII XY, or BIN data files" on
page 266.
Reference Waveform data (*.h5) — Saves waveform data in a format that
can be recalled to one of the oscilloscope's reference waveform
locations. See "To save reference waveform files to a USB storage
device" on page 271.
ALB data (*.alb) — This creates an Agilent proprietary format file that
can be imported by the Agilent Logic Analyzer application software,
using the Agilent B4610A Data Import tool, for offline viewing and
analysis. See "To save ALB data files" on page 267.
Binary data (*.bin) — This creates a binary file, with a header, and data
in the form of time and voltage pairs. This file is much smaller than
the ASCII XY data file. See "To save CSV, ASCII XY, or BIN data
files" on page 266.
Lister data (*.csv) — This is a CSV format file containing serial decode
row information with commas separating the columns. See "To save
Lister data files" on page 271.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies InfiniiVision 3000 MSO-X 3012A and is the answer not in the manual?

Agilent Technologies InfiniiVision 3000 MSO-X 3012A Specifications

General IconGeneral
BrandAgilent Technologies
ModelInfiniiVision 3000 MSO-X 3012A
CategoryTest Equipment
LanguageEnglish

Related product manuals