AKYAPAK-AHS-UserManual-2019.03.11
Motor rotating direction is indicated on the motor. Stop the motor immediately if it is
rotating in the wrong direction. (For 3 seconds) If the electrical connection is wrong,
disconnect power. Try again after replacing the phases of the sockets.
Machine is now ready for operation.
To replace hydraulic oil:
• Set the cylinder rotating speed to maximum.
• That is, move cylinders up and down for 30 minutes minimum.
• There is a warning light that indicates dirtiness rate on hydraulic return filter.
If the arrow indicates green zone, you can continue your operation, but if the arrow
indicates red zone, you may continue your operation after replacing hydraulic return filter.